Helping Fix the PC Monitors with Windows Server Monitoring

Present day article talks about repairing the CMV 19" LCD Monitor problems model Centimetres-922D. The complain wasn't energy as exactly what the customer known to. This energy supply wasn't incorporated within the circuit consequently it require an exterior energy adapter to energy up. The input for your LCD Monitor is 19V with 3.1 Amplifier within the adapter. Since the complain wasn't energy, we have to test that to find out once the energy adapter should be to blame or even the LCD Monitor. My windows server monitoring guy was the one that was speaking for me personally relevant with this particular. The ac supply was blocked for that energy adapter that we saw the power Introduced was lighted up. Analyzing the output current inside the energy adapter I obtained about 19 volts that's good. Even though the Introduced has lit and proper output current, this doesn't imply the power adapter can maintain when there's lots (the LCD Monitor) connected from it. After i discovered a Compaq 17" LCD Monitor that have a precise output current within the energy adapter however, if connected to the Monitor, the display showed up in this area for part of another before shutting lower. Usually throughout this case, your experienced would inform you that it might be the inverter circuit are faulty or even the lamps have problem.

You would be surprised the particular reason for the shutdown was due to the power adapter. It can't sustain the output current when there's lots relating to this. This kind of fault was normally due to a poor filter capacitors located in the development of the secondary circuit. For individuals who've ESR meter, you'll be capable of really locate the defective electrolytic capacitors fast. Without acquiring the meter, just direct switch the caps. As pointed out inside my previous repair articles, to make certain once the energy adapter is actually working or else you will need a light some factor like a load, according to my windows server monitoring buddy. Make certain the power Introduced light doesn't blink whenever the sun's rays is connected. Even if it blinks once, this proves the regulation is not good and need to be check entirely. Inside the above china made LCD Monitor, the power adapter work perfectly fine! Since I Have Have Have Have have formerly confirmed the power adapter is great, my focus now was over the LCD boards. Eliminating this cover was quite simple and you'll easily convenience board when the metal casing was removed. The very first ingredient that we checked was the SMD fuse situated inside the primary board.

Once the fuse opens then there'd be no supply for your ADC/SCALAR together with the CPU IC thus the power Introduced wouldn't light! Checking this SMD fuse was easy since the method of checking it is the same as like a normal fuse. Use either an analog or perhaps a digital meter set to ohms range or continuity check. You may also examine the fuse despite the fact that it's still in circuit. Yes, the fuse was seen being open circuit. Now there's one question that needs to be clarified by us. Why the fuse to go to open circuit? Well from all you have known electronic repair, you'll find three options as why a fuse opens circuit, my windows server monitoring friend known to. First, the fuse can become open circuit due to its lifespan. Some fuses needs a super very long time even though some only couple of years. Basically, the existence length of the fuse depends over the qualities inside the materials used. Next, the outside factor like a surge creating the fuse to start circuit to manage to safeguard the main board. Third, the main board itself have problem (like a shorted IC's as well as other electronic components) that triggered the fuse to start circuit.

No comments:

Post a Comment